Esposito Chimney Care

Tenant fireplaces: what is checked and what is written down

Price a building

The safety items that head every unit sheet

A tenant treats the fireplace as part of the furniture. It may hold candles for three years and then be lit on the first cold night in December by someone who has never worked the damper. The sheet we fill in for each unit is written with that evening in mind.

Five items come before anything else, and each is answered yes or no with a photograph where a picture helps. The remainder of the Level 1 visual inspection follows underneath: firebox, the visible flue, and the cap as seen from outside.

  • Carbon monoxide alarm: is one fitted close to the fireplace, and does it sound when its test button is pressed?
  • Damper: does it open fully and hold there, and on a gas log set is it fixed so that it cannot be shut?
  • Flue: is daylight visible, or do nesting, leaves or fallen tile stand in the way?
  • Gas shutoff: can a tenant reach it, and does it turn?
  • Hearth and surround: is anything that burns stored on the hearth or pushed against the opening?

Where carbon monoxide comes from in a fireplace unit

Every fire makes carbon monoxide, and a sound flue carries all of it outdoors. It reaches the room when that path is cut. A nest in the top of the flue will do it. So will a damper someone closed to stop a draft and forgot, a gas burner so sooted that it burns badly, or a strong kitchen fan in a tight apartment drawing air back down the chimney. Gas makes the case worse, because there is no smoke to warn anyone.

State law puts a carbon monoxide alarm in each dwelling unit that has a fireplace, a fuel-burning appliance or an attached garage, and it puts the upkeep of that alarm on the owner. The alarm speaks up once something has already gone wrong. An inspection deals with the four causes above before a tenant strikes a match.

What a manager holds afterwards

Each fireplace gets its own dated sheet: unit number, masonry or factory-built, wood or gas, the five safety answers, the other findings and the photographs. A unit that should not be used carries the reason in a single sentence, in words that can be lifted straight into a notice to the tenant.

A building summary sits on top. It lists every unit visited, every unit we could not enter, and every unit with an open item, so an owner, a board or an insurer who asks what was done about the fireplaces can be answered with one page and a date.

Entry, notice and occupied units

Notice to tenants is the manager's side of the arrangement and goes out under your lease terms. On the day a staff member walks the route with a key, or tenants let us in themselves. Units that stayed locked are listed by number on the summary, so that nobody later assumes they were seen.

When a fireplace fails a safety item, your on-site contact is told before we leave the property and the fireplace is tagged at the opening. Repairs are quoted afterwards, unit by unit. The board or the owner can then approve the urgent ones without waiting on the others.

Billed by the fireplace

No hourly rate and no building fee. A complex with thirty hearths pays the first line thirty times.

Visual safety inspection, each fireplace
$165
Sweeping a wood-burning flue the inspection shows is due, each
from $425
Filmed inspection for a unit with an open question or a sale pending
$395

Repairs are quoted in writing per unit once the sheets are complete.

Questions from managers and boards

Is the carbon monoxide alarm the owner's job or the tenant's?

The owner's. California's rule applies to dwelling units with a fireplace, a fuel-burning appliance or an attached garage. The owner fits the alarm and keeps it working, and the tenant is expected to report one that has stopped. Our sheet records whether an alarm was there and whether it sounded. We do not sell alarms.

A tenant reports a smell from the fireplace. What should happen before your visit?

Ask the tenant to leave it unlit, write down the date and the description, and book that unit. A smell of gas is different: the gas utility is called first, from outside the unit, and we come once the utility has been.

What does a do-not-use finding mean in an occupied unit?

The sheet names the hazard, the opening is tagged and your contact hears about it before we drive away. How the tenant is notified in writing is your decision, and the sentence on the sheet is there to be reused.

Our buildings are all gas. Is this still needed?

Yes. A gas flame gives off no smoke, so a blocked vent goes unnoticed in the room, and that is the situation the carbon monoxide lines exist for. The figure per fireplace is the same $165.

How often should the units be seen?

NFPA 211 asks for every chimney, fireplace and vent in service to be inspected once a year. Many managers in Orange place the visit in early autumn, ahead of the months when tenants light fires, and add a unit whenever it changes hands.

How many fireplaces are in the building?

Our contact page has the form. Enter the property name, the count of fireplace units and the fuel they burn. We answer with the total and the plan for getting into each unit.

Call (657) 233-4699
Call (657) 233-4699